Factory Equipment Air filtration

Startseite Market Segments & Applications Factory Equipment Air Filtration Nuclear power plants – Use of Clear Edge compact filter elements

Clear Edge Compact Filter Elements in nuclear power plants

Company ESR is specialized in the production of individual extraction and dedusting systems. The suitable separation system is selected taking into account the type and quantity of substances to be separated. The physical and chemical properties as well as the respective physical state are of utmost importance. In addition ot the series devices, systems specially developed are also built, to meet customer requirements. Furthermore, the conversion and refurbishment of old systemss is also offered.

Challenge

The dismantling of nuclear power plant produces carcinogenic cement dust, which must be extracted. The dismantling of a nuclear power plant takes place from the inside to the outside. First, the more radioactively contaminated parts of the plant in the controlled area are dismantled in order to reduce the radiation exposure for the personell as far as possible. The reactor components are crushed under water. This shields the radiation and prevents the release of dust into the air.

Technical specifications

  • Volume flow: 80,000 m³/h
  • Particle size: 70 % of the particles approx. 0.4 µm
  • Filter elements: 500 x 1200 mm
  • Filter class: dust class „M“ according to DIN EN 60335-2-6
  • Filter area: 4.1 m² / total 1,050 m²
  • Filter medium: polyester fleece with microporous coating
  • Filter surface load: 76,2 m³/(m²h)
  • Pressure loss (plant in operation): ~ 800 – 1600 Pa
  • Max. final pressure difference (Δp): 2.200 Pa

Solution statement

  • Filter material of dust class „M“, certified according to DIN EN 60335-2-69-2008, for use in dust-removing machines and devices
  • PMF is certified according to BIA dust class M by IFA
  • Service life even with increased air humidity
  • Hydrophobic properties of the carrier material
  • Low space requirements due to as much filter surface area as possible in the smallest space, with simultaneous high filter surface load
  • Filter element 8.1, dimension 500 x 1.200 with 60 folds, enlargement of the filter area from 2.8 m² to 4.1 m²

Customer value

  • Implementation of requirements in the tightest of spaces
  • Low downtime costs due to long service life of the elements
  • Simplified approval planning by the authorities with DIN certificates
  • Experience for further projects

Downloads