Reduce energy consumption and increase air volume!
Electrical energy consumption was reduced by more than 20 percent. This was achieved by modernizing an existing air compressor system with a new blower station from KAESER Kompressoren SE.
The central blower station had to be modernized at a wastewater treatment plant used for 85,000 inhabitants. Here, four older frequency-controlled rotary blowers generated the compressed air, which was distributed to the individual activated sludge zones via a manifold with orifice regulating gates. In the case of a new plant, the requirement was to reduce the electrical energy demand considerably and thus to better adapt the compressed air generators running in the interconnected system to the air demand, which fluctuates strongly seasonally e.g. as a result of the grape harvest. Half of all cascades are ventilated intermittently. The new systems must undergo a performance test in accordance with ISO 1217 Annex C or E before delivery.